What Is 500 Mcm Cable Used For?

What is MCM wire used for?

MCM is generally used for very large-diameter wire.

Most wire uses AWG.

MCM is also used for “million cubic meters.”.

What is the ampacity of 500 MCM?

Table 310.15(B)(17)SizeTemperature Rating of Copper Conductor(AWG or kcmil)60°C (140°F)75°C (167°F)350 KCMIL420505400 KCMIL455545500 KCMIL51562027 more rows

Is 500 Kcmil the same as 500 MCM?

MCM is the old way of denoting the size, and kcmil is the newer way of stating the same thing. So, here is an example of how this works: Lets say you are pulling a run of 500 MCM or 500 KCMIL. That means you are pulling a conductor that has a cross section of 500,000 circular mils.

How much does a foot of 500 MCM copper weigh?

1.680LBS per footHow much does 500 mcm copper wire weigh per foot? 1.680LBS per foot …

What does 4 0 copper weigh per foot?

AWG Copper Wire Size and Data Table Chart @ 100 Degrees FAWGDiameterWeight(in)lb/1000 ft0000 (4/0)0.4600640.5000 (3/0)0.4096507.900 (2/0)0.3648402.841 more rows

How many amps can 10 gauge wire handle at 12 volts?

The maximum current in a gauge #10 (5.26 mm2) cable with length 15 m is approximately 5 amps.

How is Kcmil calculated?

mil area directly from table. Multiply the width of the wire cross Multiply the width of the wire section in mils by the thickness of cross section in millimeters by the wire cross section in mils by the thickness in millimeters by 1.2732 and subtract the radius 1973.525 and subtract the radius factor included below.

What size wire do I need for 200 amp service?

SERVICE ENTRANCE CONDUCTORS SIZE AND RATINGService or Feeder RatingCopper ConductorsAluminum or Copper-Clad Aluminum125 Amps#2 AWG#1/0 AWG150 Amps#1 AWG#2/0 AWG200 Amps#2/0 AWG#4/0 AWG1 more row

What is bigger 4 0 or 250 MCM?

Circular Mils Kcmil sizes are used instead of AWG for sizes larger than 4/0 AWG. The smallest standard size is 250 kcmil, the largest 2000 kcmil.

What is the difference between Kcmil and MCM?

MCM is an abbreviation for thousands of circular mils, an old measurement of wire gauge. 1 MCM = 1 kcmil = 0.5067 square milimeters. A mil is 1/1000 inch. … MCM is generally used for very large-diameter wire.

What is the largest electrical wire size?

0.50 inchesNo. 7/0, the largest size, is 0.50 inches (500 mils or 12.7 mm) in diameter (1570 circular mils area), and the smallest, No. 50, is 0.001 inches (1 mil or 25.4 μm) in diameter (80 circular mils area).

What is the outside diameter of 500 mcm cable?

WIRE SIZE / STRANDINGApprox. Insulation Outside DiameterAWG / kcmilStrandsDia Inches500370.925600611.026750611.12821 more rows

What wire do you use for 100 amp service?

When it comes to the lines connecting master and secondary panels, where the line will carry as much as a full 100 amps, use a 2-gauge non-metallic sheathed electrical cable. The cable must contain one or two hot wires depending on your needs, one neutral wire, and one ground wire. Each wire should be 2-gauge in size.

What Kcmil 250?

For example, one common wire size used in the NEC has a cross-section of 250,000 circular mils, written as 250 kcmil or 250 MCM, which is the first size larger than 0000 AWG used within the NEC. …

How many amps is number 2 GOOD FOR?

Ampacities of Wire Types (w/ Temp Rating) @ 0-2000 VoltsWire Size AWGTW, UF (140°)FEPW, RH, RHW, THHW, ZW, THWN, XHHW, THW, USE (167°)11101302951153851004708513 more rows